5 Essential Elements For Floor Humidity Tester
5 Essential Elements For Floor Humidity Tester
Blog Article
ATTAR (Advanced Technology Testing & Research)
44/48 Rocco Dr, Scoresby VIC 3179, Australia
+61 1300 139 155
https://maps.app.goo.gl/RoEp6iupmJCuiUxk6
When it concerns guaranteeing safety in industrial, commercial, and residential spaces, slip resistance testing is an important factor. At ATTAR (Advanced Technology Testing & Research), we concentrate on floor slip resistance testing, concrete moisture testing, and luminance contrast analysis to help organizations and property owners alleviate risks and comply with security requirements.
With state-of-the-art equipment such as the pendulum slip test maker and moisture meter for concrete, we provide precise and independent slip testing services throughout Australia. Our know-how covers ASTM F2170 compliance, R Rating evaluations, P Ranking tiles, and more, ensuring your floorings satisfy the greatest security standards.
Why Slip Resistance Testing is Essential
Slips and falls are among the leading causes of workplace and public injuries. Appropriate slip testing assists recognize hazardous surfaces before accidents happen. Whether you require damp pendulum test examinations or pendulum test for slip resistance, ATTAR delivers precise results to improve security.
Secret Services Provided by ATTAR
1. Floor Slip Resistance Testing
- Pendulum slip test (AS 4663).
- R Ranking and P Ranking tiles evaluations.
- Independent slip testing services for compliance.
2. Concrete Moisture Testing
- Slab moisture test utilizing innovative moisture meter for concrete.
- ASTM F2170 compliant assessments.
- Concrete slab moisture testing to prevent flooring failures.
3. Luminance Contrast Testing
- Guarantees presence for aesthetically impaired people.
- Complies with Australian ease of access requirements.
4. On-Site & Lab Testing
- Slip test machine for accurate on-site evaluations.
- Wet pendulum test for damp surface slip resistance.
Comprehending Slip Resistance Rankings: R Rating vs. P Rating
When carrying out slip resistance testing, 2 key classifications are used:.
- R Ranking (Ramp Test - DIN 51130)
Procedures slip resistance under lubricated conditions, frequently utilized in Europe.
- P Ranking (Pendulum Test - AS 4586)
Examines vibrant friction utilizing a pendulum test slip resistance machine, widely adopted in Australia.
ATTAR offers independent slip testing to identify whether your floor covering fulfills the required pendulum score tiles standards.
The Significance of Concrete Moisture Testing
Excess moisture in concrete slabs can result in flooring failures, mold growth, and adhesive degradation. Our concrete moisture testing services include:.
> ASTM F2170 compliant in-situ relative humidity testing.
> Moisture meter for concrete assessments.
> Slab moisture test to make sure optimum conditions for floor installations.
By identifying moisture issues early, we assist prevent costly repair work and make sure long-lasting flooring performance.
Luminance Contrast for Availability Compliance
Appropriate luminance contrast is vital for visually impaired people to navigate spaces safely. ATTAR evaluates:.
> Stair edges.
> Door frames.
> Handrails.
> Tactile indications.
Our evaluations guarantee compliance with Australian Disability Standards (AS 1428.1).
Why Pick ATTAR for Slip Resistance & Moisture Testing?
> NATA Accredited (where appropriate).
> Advanced Testing Devices (pendulum slip test, moisture meters).
> Nationwide Service Protection.
> Fast & Trusted Reporting.
For professional slip resistance testing, floor slip resistance testing, and concrete moisture testing, contact ATTAR (Advanced Technology Testing & Research):.
Address: 44/48 Rocco Dr, Scoresby VIC 3179, Australia.
Phone: +61 1300 139 155.
Common Applications of Slip Resistance Testing
1. Commercial & Retail Spaces
Shopping center, restaurants, and workplaces require safe flooring to prevent consumer and staff member injuries. Our pendulum slip test ensures compliance with security guidelines.
2. Industrial & Warehouse Facilities
High-traffic industrial environments need long lasting, slip-resistant flooring. ATTAR's slip testing services assist keep work environment safety.
3. Health Care & Aged Care Facilities
Healthcare facilities and nursing homes need to lessen slip risks. Our luminance contrast and slip resistance testing make sure safe movement for clients and personnel.
4. Public Facilities
Walkways, train stations, and federal government structures require independent slip testing to satisfy availability and safety requirements.
How ATTAR Carries Out Slip Resistance Testing
Action 1: Surface Assessment
We examine flooring products and conditions (dry, damp, or contaminated).
Action 2: Pendulum Slip Test (AS 4663)
Utilizing a slip test machine, we determine the vibrant coefficient of friction (DCOF).
Step 3: Wet Pendulum Test
Replicates slippery conditions to assess real-world slip dangers.
Step 4: Reporting & Compliance Accreditation
Detailed reports with R Score or P Ranking tiles classifications.
The Science Behind Pendulum Slip Testing
The pendulum test slip resistance technique includes a swinging arm with a rubber slider that mimics a foot's movement. The test procedures:.
- Slip Potential Worth (SPV).
- Pendulum ranking tiles classification (P0 to P5).
Higher scores (P4/P5) show better slip resistance.
Moisture Testing for Concrete Floors: Preventing Failures
Moisture-related flooring failures can be pricey. ATTAR's concrete slab moisture testing consists of:.
- ASTM F2170 in-situ RH probes.
- Moisture meter for concrete spot checks.
- Slab moisture test data analysis.
Conclusion
ATTAR (Advanced Technology Testing & Research) is Australia's relied on provider of slip resistance testing, floor slip resistance testing, concrete moisture testing, and luminance contrast assessments. With advanced technology like the pendulum slip test and moisture meter for concrete, we provide precise, independent, and compliant testing services.
Ensure your residential or commercial property website fulfills security standards-- contact ATTAR today:.
44/48 Rocco Dr, Scoresby VIC 3179, Australia.
+61 1300 139 155.
By selecting ATTAR, you buy independent slip testing services, pendulum test slip resistance precision, and long-term floor security solutions. Let us assist you develop much safer, certified, and moisture-resistant environments. Report this page